WELCOME to My Shop Commodity, Competitive Price, Customer First!
Your business with me will be a pleasant experience for you. I am dedicated to bring joy, safe and top-quality products for you. All the products I offer in my store come with fashion style, superior quality but cheaper price all the time. When you place order, please do not hesitate to leave more detailed requirements you want, and then I will arrange the goods for you as soon as possible. First time, we do business; next time, we become friends. Hope you enjoy the whole process!
l Function:
2 Setting:
Same cost and time for start and continuations use + optional function- given time:
Set up COST and Time. Pay same cost to start or continuous using machine.
GIVEN TIME and PRICE:User can get extra free time if paid reaches pre-set value in running time.
GIVEN TIME VALUE is rate of COST
Example setting: COST- 2 dollar for 10 mins, GIVEN TIME- 2 rate for 6 mins.
Insert 2 dollars--> machine start working for 10 mins-> Insert 2 dollar in 10 mins-> add 10+6 mins (free).
User has to insert 2 dollars in 10 mins for 6 mins free.
Description
INPUT/OUTPUT Voltage | □ AC220V □ AC110V (Choose before leaving the factory) INPUT and OUTPUT Voltage HAVE TO be the same |
Standby | Display shows:00:00, rely: Normal Open (NO) |
Accumulated time | Yes, add time if receive signals again when time is running |
Max current load | 15A |
How it works | |
Mode 1 | Time runs down after receive signals-> Display shows remaining time and supply power to device-> it cuts off power after time runs out |
Mode 2 (Connect a button) | Display shows remaining time after receive signals-> push button start-> time runs down and supply power to device-> it cuts off power after time runs out |
Pause (connect a button) | Push button pause: it cuts off power when pause, display shows remaining time. Re-supply power after push button pause again |
Voltage Checking Connector Summary
Please press button "S4" 4 TIMES. “B” flashes. Please set up RATE OF INPUT SIGNAL QUANTITY.
Please press button "S4", “A” flashes. Please set up GIVEN TIME.
Please press button "S4", “B” flashes. Please set up GIVEN TIME.
Please press button "S4" to finish.
GIVEN TIME:Add time by free if input signals reach SETTING RATE during time is running.
Example Setting: input signal to active device: 01, input signals for given time: 03 give time: 02:10
Add time “02:10” free if receive “3 signals” during time is running.
Please press button "S4". “B” flashes. Please set up INPUT SIGNAL QUANTITY to active device (01-50).
Please press button "S4", “A” flashes. Please set up TIME (01-99).
Please press button "S4", “B” flashes. Please set up TIME (01-99).
Please press button “S4” 4 TIMES.
Please set up TIME for Warning Sound.
Please press button "S4" to finish.
INPUT SIGNAL QUANTITY AND TIME
Please follow CODE ON DISPLAY and use button "S1" and "S2" to set up number
Cost and Time Setup
H (RED):+DC12V G (WHITE): signal input F (BLACK) : GND E (BLUE): counter
15: Connect to coin acceptor or bill acceptor:
14: Connect to counter: D (BLACK): GND C (RED):+DC12V B (WHITE): signal output
10-13: Setting buttons:10: button S4,11: button S2,12: button S3,13: button S1
7: Input power: N8: FG9: Input power L
4: Button STOP/Continue5: Output power: L6: Output power: N
1: Display2: White lead3: Button START for operating model:01:02
Connection
-------------------------------------------------------------------------------------------------------------------Page 1-----------------------------------------------------------------------------------------------
Function | Code on Display | Description | |
A | B | ||
Running Time | 01 | 01 | Time runs down without pressing button |
02 | Time runs down by pressing button | ||
Time Type | 02 | 03 | MINUTE: SECOND |
04 | HOUR: MINUTE | ||
Memory | 03 | 05 | Yes: Remaining time keep running after power off and on |
06 | No: Standby power off and on | ||
Back to standby | 04 | 1-30 | user has no action after push buttons or receive signals in setting time |
Default: 01-03: Bold and base line. 04: not use the function. |
Please hold on button "S1" and "S2" simultaneously for 3 seconds to get intoMODE SETTING.
Please use button "S1" and button "S2" to set up number forCODE
Please press button "S4" to switch to next code
Please follow table to set up operating function:
Mode Setting
|